Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 136.236
Filter
1.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38562639

ABSTRACT

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Shoulder Prosthesis , Humans , Arthroplasty, Replacement, Shoulder/methods , Shoulder Joint/surgery , Shoulder/surgery , Scapula , Range of Motion, Articular , Biomechanical Phenomena
2.
PLoS One ; 19(4): e0300108, 2024.
Article in English | MEDLINE | ID: mdl-38568899

ABSTRACT

Delving into the complexities of embodied cognition unveils the intertwined influence of mind, body, and environment. The connection of physical activity with cognition sparks a hypothesis linking motion and personality traits. Hence, this study explored whether personality traits could be linked to biomechanical variables characterizing running forms. To do so, 80 runners completed three randomized 50-m running-trials at 3.3, 4.2, and 5m/s during which their running biomechanics [ground contact time (tc), flight time (tf), duty factor (DF), step frequency (SF), leg stiffness (kleg), maximal vertical ground reaction force (Fmax), and maximal leg compression of the spring during stance (ΔL)] was evaluated. In addition, participants' personality traits were assessed through the Myers-Briggs Type Indicator (MBTI) test. The MBTI classifies personality traits into one of two possible categories along four axes: extraversion-introversion; sensing-intuition; thinking-feeling; and judging-perceiving. This exploratory study offers compelling evidence that personality traits, specifically sensing and intuition, are associated with distinct running biomechanics. Individuals classified as sensing demonstrated a more grounded running style characterized by prolonged tc, shorter tf, higher DF, and greater ΔL compared to intuition individuals (p≤0.02). Conversely, intuition runners exhibited a more dynamic and elastic running style with a shorter tc and higher kleg than their sensing counterparts (p≤0.02). Post-hoc tests revealed a significant difference in tc between intuition and sensing runners at all speeds (p≤0.02). According to the definition of each category provided by the MBTI, sensing individuals tend to focus on concrete facts and physical realities while intuition individuals emphasize abstract concepts and patterns of information. These results suggest that runners with sensing and intuition personality traits differ in their ability to use their lower limb structures as springs. Intuition runners appeared to rely more in the stretch-shortening cycle to energetically optimize their running style while sensing runners seemed to optimize running economy by promoting more forward progression than vertical oscillations. This study underscores the intriguing interplay between personality traits of individuals and their preferred movement patterns.


Subject(s)
Intuition , Running , Humans , Biomechanical Phenomena , Lower Extremity , Emotions
3.
Sci Data ; 11(1): 343, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580698

ABSTRACT

The sports industry is witnessing an increasing trend of utilizing multiple synchronized sensors for player data collection, enabling personalized training systems with multi-perspective real-time feedback. Badminton could benefit from these various sensors, but there is a scarcity of comprehensive badminton action datasets for analysis and training feedback. Addressing this gap, this paper introduces a multi-sensor badminton dataset for forehand clear and backhand drive strokes, based on interviews with coaches for optimal usability. The dataset covers various skill levels, including beginners, intermediates, and experts, providing resources for understanding biomechanics across skill levels. It encompasses 7,763 badminton swing data from 25 players, featuring sensor data on eye tracking, body tracking, muscle signals, and foot pressure. The dataset also includes video recordings, detailed annotations on stroke type, skill level, sound, ball landing, and hitting location, as well as survey and interview data. We validated our dataset by applying a proof-of-concept machine learning model to all annotation data, demonstrating its comprehensive applicability in advanced badminton training and research.


Subject(s)
Athletic Performance , Racquet Sports , Wearable Electronic Devices , Biomechanical Phenomena , Lower Extremity , Racquet Sports/physiology , Humans
4.
BMC Musculoskelet Disord ; 25(1): 268, 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38582828

ABSTRACT

BACKGROUND: Knee osteoarthritis (KOA) is a prevalent and debilitating condition that markedly affects the sit-to-stand (STS) activity of patients, a prerequisite for daily activities. Biomechanical recognition of movements in patients with mild KOA is currently attracting attention. However, limited studies have been conducted solely on the observed differences in sagittal plane movement and muscle activation. AIM: This study aimed to identify three-dimensional biomechanical and muscle activation characteristics of the STS activity in patients with mild KOA. METHODS: A cross-sectional study was conducted to observe the differences between patients with mild KOA and a control group (CG). It was conducted to observe the differences in muscle activation, including root mean square (RMS%) and integrated electromyography (items), kinematic parameters like range of motion (ROM) and maximum angular velocity, as well as dynamic parameters such as joint moment and vertical ground reaction force (vGRF). RESULTS: Patients with mild KOA had a higher body mass index and longer task duration. In the sagittal plane, patients with KOA showed an increased ROM of the pelvic region, reduced ROM of the hip-knee-ankle joint, and diminished maximum angular velocity of the knee-ankle joint. Furthermore, patients with KOA displayed increased knee-ankle joint ROM in the coronal plane and decreased ankle joint ROM in the horizontal plane. Integrated vGRF was higher in both lower limbs, whereas the vGRF of the affected side was lower. Furthermore, patients showed a decreased peak adduction moment (PADM) and increased peak external rotation moment in the knee joint and smaller PADM and peak internal rotation moment in the ankle joint. The affected side exhibited decreased RMS% and iEMG values of the gluteus medius, vastus medialis, and vastus lateralis muscles, as well as a decreased RMS% of the rectus femoris muscle. Conversely, RMS% and iEMG values of the biceps femoris, lateral gastrocnemius, and medial gastrocnemius muscles were higher. CONCLUSION: The unbalanced activation characteristics of the anterior and posterior muscle groups, combined with changes in joint moment in the three-dimensional plane of the affected joint, may pose a potential risk of injury to the irritated articular cartilage.


Subject(s)
Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/diagnosis , Biomechanical Phenomena , Cross-Sectional Studies , Lower Extremity/physiology , Muscle, Skeletal/physiology , Knee Joint/physiology , Electromyography
5.
BMC Oral Health ; 24(1): 425, 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38582842

ABSTRACT

BACKGROUND: Clinical scenarios frequently present challenges when patients exhibit asymmetrical mandibular atrophy. The dilemma arises: should we adhere to the conventional All-on-4 technique, or should we contemplate placing vertically oriented implants on the side with sufficient bone mass? This study aims to employ three-dimensional finite element analysis to simulate and explore the biomechanical advantages of each approach. METHODS: A finite element model, derived from computed tomography (CT) data, was utilized to simulate the nonhomogeneous features of the mandible. Three configurations-All-on-4, All-on-5-v and All-on-5-o were studied. Vertical and oblique forces of 200 N were applied unilaterally, and vertical force of 100 N was applied anteriorly to simulate different masticatory mechanisms. The maximum von Mises stresses on the implant and framework were recorded, as well as the maximum equivalent strain in the peri-implant bone. RESULTS: The maximum stress values for all designs were located at the neck of the distal implant, and the maximum strains in the bone tissue were located around the distal implant. The All-on-5-o and All-on-5-v models exhibited reduced stresses and strains compared to All-on-4, highlighting the potential benefits of the additional implant. There were no considerable differences in stresses and strains between the All-on-5-o and All-on-5-v groups. CONCLUSIONS: With the presence of adequate bone volume on one side and severe atrophy of the contralateral bone, while the "All-on-4 concept" is a viable approach, vertical implant placement optimizes the transfer of forces between components and tissues.


Subject(s)
Dental Implants , Humans , Biomechanical Phenomena , Finite Element Analysis , Stress, Mechanical , Dental Stress Analysis/methods , Dental Prosthesis, Implant-Supported , Mandible/diagnostic imaging , Atrophy
6.
Sci Rep ; 14(1): 8160, 2024 04 08.
Article in English | MEDLINE | ID: mdl-38589521

ABSTRACT

To analyze the changing trend of CH and CRF values under different influencing factors in T2DM patients. A total of 650 patients with T2DM were included. We discovered that the course of T2DM, smoking history, BMI, and FBG, DR, HbA1c, TC, TG, and LDL-C levels were common risk factors for T2DM, while HDL-C levels were a protective factor. Analyzing the CH and CRF values according to the course of diabetes, we discovered that as T2DM continued to persist, the values of CH and CRF gradually decreased. Moreover, with the increase in FBG levels and the accumulation of HbA1c, the values of CH and CRF gradually decreased. In addition, in patients with HbA1c (%) > 12, the values of CH and CRF decreased the most, falling by 1.85 ± 0.33 mmHg and 1.28 ± 0.69 mmHg, respectively. Compared with the non-DR group, the CH and CRF values gradually decreased in the mild-NPDR, moderate-NPDR, severe-NPDR and PDR groups, with the lowest CH and CRF values in the PDR group. In patients with T2DM, early measurement of corneal biomechanical properties to evaluate the change trend of CH and CRF values in different situations will help to identify and prevent diabetic keratopathy in a timely manner.


Subject(s)
Cornea , Diabetes Mellitus, Type 2 , Humans , Glycated Hemoglobin , Biomechanical Phenomena , Intraocular Pressure , Elasticity , Tonometry, Ocular
7.
BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38589829

ABSTRACT

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Subject(s)
Bone Screws , Femoral Fractures , Humans , Bone Screws/adverse effects , Biomechanical Phenomena , Internal Fixators , Fracture Fixation, Internal , Femoral Fractures/etiology , Body Weight
8.
J Morphol ; 285(5): e21696, 2024 May.
Article in English | MEDLINE | ID: mdl-38639429

ABSTRACT

In infants and children with feeding and swallowing issues, modifying solid foods to form a liquid or puree is used to ensure adequate growth and nutrition. However, the behavioral and neurophysiological effects of prolonged use of this intervention during critical periods of postnatal oral skill development have not been systematically examined, although substantial anecdotal evidence suggests that it negatively impacts downstream feeding motor and coordination skills, possibly due to immature sensorimotor development. Using an established animal model for infant and juvenile feeding physiology, we leverage X-ray reconstruction of moving morphology to compare feeding behavior and kinematics between 12-week-old pigs reared on solid chow (control) and an age- and sex-matched cohort raised on the same chow softened to a liquid. When feeding on two novel foods, almond and apple, maintenance on a soft diet decreases gape cycle duration, resulting in a higher chewing frequency. When feeding on almonds, pigs in this group spent less time ingesting foods compared to controls, and chewing cycles were characterized by less jaw rotation about a dorsoventral axis (yaw) necessary for food reduction. There was also a reduced tendency to alternate chewing side with every chew during almond chewing, a behavioral pattern typical of pigs. These more pronounced impacts on behavior and kinematics during feeding on almonds, a tougher and stiffer food than apples, suggest that food properties mediate the behavioral and physiological impacts of early texture modification and that the ability to adapt to different food properties may be underdeveloped. In contrast, the limited effects of food texture modification on apple chewing indicate that such intervention/treatment does not alter feeding behavior of less challenging foods. Observed differences cannot be attributed to morphology because texture modification over the treatment period had limited impact on craniodental growth. Short-term impacts of soft-texture modification during postweaning development on feeding dynamics should be considered as potential negative outcomes of this treatment strategy.


Subject(s)
Feeding Behavior , Mastication , Swine , Animals , Mastication/physiology , Biomechanical Phenomena , Feeding Behavior/physiology , Diet , Growth and Development
9.
Bioinspir Biomim ; 19(3)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38569526

ABSTRACT

Computational models are used to examine the effect of schooling on flow generated noise from fish swimming using their caudal fins. We simulate the flow as well as the far-field hydrodynamic sound generated by the time-varying pressure loading on these carangiform swimmers. The effect of the number of swimmers in the school, the relative phase of fin flapping of the swimmers, and their spatial arrangement is examined. The simulations indicate that the phase of the fin flapping is a dominant factor in the total sound radiated into the far-field by a group of swimmers. For small schools, a suitable choice of relative phase between the swimmers can significantly reduce the overall intensity of the sound radiated to the far-field. The relative positioning of the swimmers is also shown to have an impact on the total radiated noise. For a larger school, even highly uncorrelated phases of fin movement between the swimmers in the school are very effective in significantly reducing the overall intensity of sound radiated into the far-field. The implications of these findings for fish ethology as well as the design and operation of bioinspired vehicles are discussed.


Subject(s)
Fishes , Models, Biological , Animals , Biomechanical Phenomena , Swimming , Schools
10.
Traffic Inj Prev ; 25(4): 640-648, 2024.
Article in English | MEDLINE | ID: mdl-38578292

ABSTRACT

OBJECTIVE: Occupant impact safety is critical for train development. This paper proposes a systematic procedure for developing validated numerical occupant crash scenarios for high-speed trains by integrating experimental, computational, and inverse methods. METHODS: As the train interior is the most potentially injury-causing factor, the material properties were acquired by mechanical tests, and constitutive models were calibrated using inverse methods. The validity of the seat material constitutive model was further verified via drop tower tests. Finite element (FE) and multibody (MB) models of train occupant-seat interactions in frontal impact were established in LS-DYNA and MADYMO software, respectively, using the experimentally acquired materials/mechanical characteristics. Three dummy sled crash tests with different folding table and backrest configurations were conducted to validate the numerical occupant-seat models and to further assess occupant injury in train collisions. The occupant impact responses between dummy tests and simulations were quantitatively compared using a correlation and analysis (CORA) objective rating method. RESULTS: Results indicated that the experimentally calibrated numerical seat-occupant models could effectively reproduce the occupant responses in bullet train collisions (CORA scores >80%). Compared with the train seat-occupant MB model, the FE model could simulate the head acceleration with slightly more acceptable fidelity, however, the FE model CORA scores were slightly less than for the MB models. The maximum head acceleration was 30 g but the maximum HIC score was 17.4. When opening the folding table, the occupant's chest injury was not obvious, but the neck-table contact and "chokehold" may potentially be severe and require further assessment. CONCLUSIONS: This study demonstrates the value of experimental data for occupant-seat model interactions in train collisions and provides practical help for train interior safety design and formulation of standards for rolling stock interior passive safety.


Subject(s)
Accidents, Traffic , Thoracic Injuries , Humans , Neck , Acceleration , Sitting Position , Biomechanical Phenomena
11.
J Biomech ; 166: 112052, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38560959

ABSTRACT

An important performance determinant in wheelchair sports is the power exchanged between the athlete-wheelchair combination and the environment, in short, mechanical power. Inertial measurement units (IMUs) might be used to estimate the exchanged mechanical power during wheelchair sports practice. However, to validly apply IMUs for mechanical power assessment in wheelchair sports, a well-founded and unambiguous theoretical framework is required that follows the dynamics of manual wheelchair propulsion. Therefore, this research has two goals. First, to present a theoretical framework that supports the use of IMUs to estimate power output via power balance equations. Second, to demonstrate the use of the IMU-based power estimates during wheelchair propulsion based on experimental data. Mechanical power during straight-line wheelchair propulsion on a treadmill was estimated using a wheel mounted IMU and was subsequently compared to optical motion capture data serving as a reference. IMU-based power was calculated from rolling resistance (estimated from drag tests) and change in kinetic energy (estimated using wheelchair velocity and wheelchair acceleration). The results reveal no significant difference between reference power values and the proposed IMU-based power (1.8% mean difference, N.S.). As the estimated rolling resistance shows a 0.9-1.7% underestimation, over time, IMU-based power will be slightly underestimated as well. To conclude, the theoretical framework and the resulting IMU model seems to provide acceptable estimates of mechanical power during straight-line wheelchair propulsion in wheelchair (sports) practice, and it is an important first step towards feasible power estimations in all wheelchair sports situations.


Subject(s)
Sports , Wheelchairs , Humans , Biomechanical Phenomena , Acceleration , Exercise Test
12.
J Biomech ; 166: 112070, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38569456

ABSTRACT

Cement-augmentation is a technique commonly used during posterior lumbar instrumented fusion (PLIF) to reinforce compromised osteoporotic vertebral bone, minimize the risk of loosening screws, enhance stability, and improve overall surgical outcomes. In this study, we introduce a novel segmented vertebral body regional modeling approach to investigate the effects of osteoporosis and cement-augmented lumbar fusion on disc biomechanics at spinal levels adjacent to the fused vertebrae. Using our previously validated personalized-poroelastic-osteoligamentous FE model of the spine, fusion was simulated at L4-L5, and the biomechanics of adjacent levels were studied for 30 patients (non-osteoporotic patients (N = 15), osteoporotic patients (N = 15)). PLIF models, with and without cement-augmentation, were developed and compared after an 8 h-rest period (200 N), following a 16 h-cyclic compressive loading of 500-1000 N (40 and 20 min, respectively). Movement in different directions (flexion/ extension/ lateral bending/ axial rotation) was simulated using 10Nm moment before and after cyclic loading. The material mapping algorithm was validated by comparing the results of voxel-based and parametric models. The FE cement-augmented models, subject to daily activity loading, demonstrated significant differences in disc height loss and fluid loss as compared to non-cemented models. The calculated axial stress and fiber strain values were also significantly higher for these models. This work demonstrates that although osteoporosis does not significantly alter the time-dependent characteristics of adjacent IVDs post-surgery, cement-augmentation increases the risk of adjacent segment disease (ASD) incidence. A holistic understanding of the trade-offs and long-term complex interplay between structural reinforcement modalities, including cement augmentation, and altered biomechanics warrants further investigation.


Subject(s)
Osteoporosis , Spinal Fusion , Humans , Finite Element Analysis , Lumbar Vertebrae/surgery , Osteoporosis/surgery , Bone Cements , Spinal Fusion/adverse effects , Biomechanical Phenomena
13.
J Biomech ; 166: 112066, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38574563

ABSTRACT

Precise measurement of joint-level motion from stereo-radiography facilitates understanding of human movement. Conventional procedures for kinematic tracking require significant manual effort and are time intensive. The current work introduces a method for fully automatic tracking of native knee kinematics from stereo-radiography sequences. The framework consists of three computational steps. First, biplanar radiograph frames are annotated with segmentation maps and key points using a convolutional neural network. Next, initial bone pose estimates are acquired by solving a polynomial optimization problem constructed from annotated key points and anatomic landmarks from digitized models. A semidefinite relaxation is formulated to realize the global minimum of the non-convex problem. Pose estimates are then refined by registering computed tomography-based digitally reconstructed radiographs to masked radiographs. A novel rendering method is also introduced which enables generating digitally reconstructed radiographs from computed tomography scans with inconsistent slice widths. The automatic tracking framework was evaluated with stereo-radiography trials manually tracked with model-image registration, and with frames which capture a synthetic leg phantom. The tracking method produced pose estimates which were consistently similar to manually tracked values; and demonstrated pose errors below 1.0 degree or millimeter for all femur and tibia degrees of freedom in phantom trials. Results indicate the described framework may benefit orthopaedics and biomechanics applications through acceleration of kinematic tracking.


Subject(s)
Knee Joint , Knee , Humans , Biomechanical Phenomena , Radiography , Knee Joint/diagnostic imaging , Knee/diagnostic imaging , Tomography, X-Ray Computed/methods , Imaging, Three-Dimensional/methods
14.
J Biomech ; 166: 112069, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38579560

ABSTRACT

We assessed the effects of a passive, back-support exoskeleton (BSE) on lower-limb joint kinetics during the initiation and swing phases of recovery from a forward loss of balance. Sixteen (8M, 8F) young, healthy participants were released from static forward-leaning postures and attempted to recover their balance with a single-step while wearing a BSE (backXTM) with different levels of support torque and in a control condition. The BSE provided âˆ¼ 15-20 Nm of external hip extension torque on the stepping leg at the end of initiation and beginning of swing phases. Participants were unable to generate sufficient hip flexion torque, power, and work to counteract this external torque, although they sustained hip flexion torque for a more prolonged period, resulting in slightly increased hip contribution to positive leg work (compared to control). However, net positive leg work, and the net contribution of hip joint (human + BSE) to total leg work decreased with BSE use. While all participants had changes in hip joint kinetics, a significant compensatory increase in ankle contribution to positive leg work was observed only among females. Our results suggest that BSE use adversely affects reactive stepping by decreasing the stepping leg kinetic energy for forward propulsion, and that the relative contributions of lower-limb joints to total mechanical work done during balance recovery are altered by BSE use. BSEs may thus need to be implemented with caution for dynamic tasks in occupational settings, as they may impair balance recovery following a forward loss of balance.


Subject(s)
Exoskeleton Device , Female , Humans , Knee Joint , Lower Extremity , Hip Joint , Ankle , Biomechanical Phenomena
15.
PLoS One ; 19(4): e0297910, 2024.
Article in English | MEDLINE | ID: mdl-38603690

ABSTRACT

Dynamic knee valgus (DKV) occurs during landing after a fatigue task involving the lower extremity. However, the manner in which different peripheral fatigue tasks affect DKV remains unknown. In this study, we investigated the DKV via electromyography during single-leg landing considering the hip-joint fatigue task (HFT) and knee-joint fatigue task (KFT) performed by healthy men. We recruited 16 healthy male participants who performed a single-leg jump-landing motion from a height of 20 cm before and after an isokinetic hip abduction/adduction task (HFT) and knee extension/flexion task (KFT). Three-dimensional motion analysis systems were attached to the left gluteus medius and quadriceps, and surface electromyography was used to analyze the lower limb kinematics, kinetics, and muscle activity. The primary effects and interactions of the task and fatigue were identified based on the two-way repeated-measures analysis of variance. The results of the average angle during landing indicated that DKV occurs in KFT, whereas HFT applies external forces that adduct and internally rotate the knee at peak vertical ground reaction force (vGRF). Furthermore, both KFT and HFT exhibited an increase in muscle activity in the quadriceps. The analysis revealed that the occurrence of DKV varies depending on the peripheral fatigue task, and the effects on average DKV during landing and DKV at peak vGRF vary depending on the peripheral fatigue task.


Subject(s)
Anterior Cruciate Ligament Injuries , Leg , Humans , Male , Biomechanical Phenomena , Lower Extremity/physiology , Muscle, Skeletal/physiology , Knee Joint/physiology
16.
Clin Biomech (Bristol, Avon) ; 114: 106236, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38564981

ABSTRACT

BACKGROUND: Obesity impacts a child's ability to walk with resulting biomechanical adaptations; however, existing research has not comprehensively compared differences across the gait cycle. We examined differences in lower extremity biomechanics across the gait cycle between children with and without obesity at three walking speeds. METHODS: Full gait cycles of age-matched children with obesity (N = 10; BMI: 25.7 ± 4.2 kg/m2) and without obesity (N = 10; BMI: 17.0 ± 1.9 kg/m2) were analyzed at slow, normal, and fast walking speeds. Main and interaction effects of group and speed across hip, knee, and ankle joint angles and moments in sagittal, frontal, and transverse planes were analyzed using one-dimensional statistical parametric mapping. FINDINGS: Compared to children without obesity, children with obesity had greater hip adduction during mid-stance, while also producing greater hip extensor moments during early stance phase, abductor moments throughout most of stance, and hip external rotator moments during late stance. Children with obesity recorded greater knee flexor, knee extensor and knee internal rotator moments during early stance, and knee external rotator moments in late stance than children without obesity; children with obesity also demonstrated greater ankle plantarflexor moments throughout mid and late stance. Interaction effects existed within joint kinetics data; children with obesity produced greater hip extensor moments at initial contact and toe-off when walking at fast compared to normal walking speed. INTERPRETATION: While few kinematic differences existed between the two groups, children with obesity exhibited greater moments at the hip, knee, and ankle during critical periods of controlling and stabilizing mass.


Subject(s)
Pediatric Obesity , Walking Speed , Child , Humans , Gait , Walking , Knee Joint , Ankle Joint , Biomechanical Phenomena
17.
J Biomech ; 167: 112064, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38582005

ABSTRACT

Biomechanical time series may contain low-frequency trends due to factors like electromechanical drift, attentional drift and fatigue. Existing detrending procedures are predominantly conducted at the trial level, removing trends that exist over finite, adjacent time windows, but this fails to consider what we term 'cycle-level trends': trends that occur in cyclical movements like gait and that vary across the movement cycle, for example: positive and negative drifts in early and late gait phases, respectively. The purposes of this study were to describe cycle-level detrending and to investigate the frequencies with which cycle-level trends (i) exist, and (ii) statistically affect results. Anterioposterior ground reaction forces (GRF) from the 41-subject, 8-speed, open treadmill walking dataset of Fukuchi (2018) were analyzed. Of a total of 552 analyzed trials, significant cycle-level trends were found approximately three times more frequently (21.1%) than significant trial-level trends (7.4%). In statistical comparisons of adjacent walking speeds (i.e., speed 1 vs. 2, 2 vs. 3, etc.) just 3.3% of trials exhibited cycle-level trends that changed the null hypothesis rejection decision. However 17.6% of trials exhibited cycle-level trends that qualitatively changed the stance phase regions identified as significant. Although these results are preliminary and derived from just one dataset, results suggest that cycle-level trends can contribute to analysis bias, and therefore that cycle-level trends should be considered and/or removed where possible. Software implementing the proposed cycle-level detrending is available at https://github.com/0todd0000/detrend1d.


Subject(s)
Gait , Walking , Walking Speed , Time Factors , Exercise Test , Biomechanical Phenomena
18.
J Biomech ; 167: 112068, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38582004

ABSTRACT

Intervertebral disc (IVD) degeneration includes changes in tissue biomechanics, physical attributes, biochemical composition, disc microstructure, and cellularity, which can all affect the normal function of the IVD, and ultimately may lead to pain. The purpose of this research was to develop an in-vitro model of degeneration that includes the evaluation of physical, biomechanical, and structural parameters, and that does so over several load/recovery periods. Hyperphysiological loading was used as the degenerative initiator with three experimental groups employed using bovine coccygeal IVD specimens: Control; Single-Overload; and Double-Overload. An equilibrium stage comprising a static load followed by two load/recovery periods was followed by six further load/recovery periods. In the Control group all load/recovery periods were the same, comprising physiological cyclic loading. The overload groups differed in that hyperphysiological loading was applied during the 4th loading period (Single-Overload), or the 4th and 5th loading period (Double-Overload). Overloading led to a significant reduction in disc height compared to the Control group, which was not recovered in subsequent physiological load/recovery periods. However, there were no significant changes in stiffness. Overloading also led to significantly more microstructural damage compared to the Control group. Taking all outcome measures into account, the overload groups were evaluated as replicating clinically relevant aspects of moderate IVD degeneration. Further research into a potential dose-effect, and how more severe degeneration can be replicated would provide a model with the potential to evaluate new treatments and interventions for different stages of IVD degeneration.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Animals , Cattle , Humans , Biomechanical Phenomena , Physical Examination , Weight-Bearing/physiology
19.
J Biomech ; 167: 112030, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38583375

ABSTRACT

Young female athletes participating in sports requiring rapid changes of direction are at heightened risk of suffering traumatic knee injury, especially noncontact rupture of the anterior cruciate ligament (ACL). Clinical studies have revealed that geometric features of the tibiofemoral joint are associated with increased risk of suffering noncontact ACL injury. However, the relationship between three-dimensional (3D) tibiofemoral geometry and knee mechanics in young female athletes is not well understood. We developed a statistically augmented computational modeling workflow to determine relationships between 3D geometry of the knee and tibiofemoral kinematics and ACL force in response to an applied loading sequence of compression, valgus, and anterior force, which is known to load the ACL. This workflow included 3D characterization of tibiofemoral bony geometry via principal component analysis and multibody dynamics models incorporating subject-specific knee geometries. A combination of geometric features of both the tibia and the femur that spanned all three anatomical planes was related to increased ACL force and to increased kinematic coupling (i.e., anterior, medial, and distal tibial translations and internal tibial rotation) in response to the applied loads. In contrast, a uniplanar measure of tibiofemoral geometry that is associated with ACL injury risk, sagittal plane slope of the lateral tibial plateau subchondral bone, was not related to ACL force. Thus, our workflow may aid in developing mechanics-based ACL injury screening tools for young, active females based on a unique combination of bony geometric features that are related to increased ACL loading.


Subject(s)
Anterior Cruciate Ligament Injuries , Humans , Female , Anterior Cruciate Ligament Injuries/complications , Knee Joint/physiology , Anterior Cruciate Ligament/physiology , Tibia/physiology , Athletes , Computer Simulation , Biomechanical Phenomena
20.
J Biomech ; 167: 112076, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38583376

ABSTRACT

Given the known deficits in spatiotemporal aspects of gait for people with Parkinson's disease (PD), we sought to determine the underlying gait abnormalities in limb and joint kinetics, and examine how deficits in push-off and leg swing might contribute to the shortened step lengths for people with PD. Ten participants with PD and 11 age-matched control participants walked overground and on an instrumented treadmill. Participants with PD then walked on the treadmill with a posteriorly directed restraining force applied to 1) the pelvis to challenge push-off and 2) the ankles to challenge leg swing. Spatiotemporal, kinematic, and force data were collected and compared between groups and conditions. Despite group differences in spatiotemporal measures during overground walking, we did not observe these differences when the groups walked on a treadmill at comparable speeds. Nevertheless, the hip extension impulse appeared smaller in the PD group during their typical walking. When challenging limb propulsion, participants in the PD group maintained step lengths by increasing the propulsive impulse. Participants with PD were also able to maintain their typical step length against resistance intended to impede swing limb advancement, and even increased step lengths with cuing. The presence of reduced hip extension torque might be an early indicator of gait deterioration in this neurodegenerative disease. Our participants with PD were able to increase hip extension torque in response to needed demands. Additionally, participants with PD were able to increase limb propulsion and leg swing against resistance, suggesting a reserve in limb mechanics.


Subject(s)
Neurodegenerative Diseases , Parkinson Disease , Humans , Walking/physiology , Gait/physiology , Leg/physiology , Biomechanical Phenomena , Walking Speed/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...